INFORMATION CENTER · OFFICE DATA CABLING

The Difference Between LSZH and CPR: Checking Labels and Documentation for Office Data Cables

LSZH refers to a "low-smoke, zero-halogen" construction; it does not, by itself, indicate the cable's CPR Euroclass rating. When purchasing office data cables, verify the full product code—along with the jacket specifications and the declared CPR class—and ensure you have the corresponding Declaration of Performance (DoP) for that specific product. Simply seeing "Cat6" or "Cat6A" labeled on a product is not a substitute for this documentation check.

A technician comparing office data cable samples against the reel label and technical documentation

LSZH and CPR: Distinguish cable category, jacket and reaction-to-fire performance

Terms like "Cat6A," "LSZH," and "Dca" found in a quote address different criteria. The category relates to data transmission performance; the jacket description refers to material properties; and the CPR classification pertains to the declared reaction-to-fire performance. Collapsing these into a single "quality score" can obscure discrepancies between the project specifications and the actual items being quoted.

For instance, on the product family page for Nexans’ LANmark-6 U/UTP line, versions with LSZH jackets—rated Eca, Dca, and Cca—are listed as distinct items with separate product codes. This demonstrates that a line item simply labeled “LSZH cable” does not specify which exact product will be delivered. Always rely on the specific product reference (part number) provided in the offer, rather than the general product family name.

LSZH and CPR: Ensure the label matches the documentation for the specific product.

Leviton’s guidance on the Construction Products Regulation (CPR) highlights the importance of the product label and the Declaration of Performance (DoP). When reviewing a purchase record, ensure you have access to the manufacturer’s current technical datasheet and the corresponding DoP. A general brand logo appearing in a sales presentation does not constitute a declaration for a specific reel of cable.

In the example of the CommScope 884050654/16 product datasheet, the LSZH specification is listed in a separate section, while the CPR classification is detailed as Dca s2, d2, a1; a link to the relevant DoP is also provided on the same page. This example applies only to that specific product and should not be interpreted as a universal classification for all CommScope cables. Do not use documentation intended for a different product reference.

A template for recording details during the quotation and delivery phases.

Check itemInformation to be recordedAction to be taken in case of a discrepancy
Product identityManufacturer, full reference, package label, and document dateDo not accept based solely on a similar family name
Jacket and categoryList Cat6/Cat6A information and LSZH/PVC designation separatelyClarify any missing information with the supplier
DeclarationEuroclass statement, sub-classes (if applicable), and link to the DoP (Declaration of Performance)Re-verify the document against the product code
Project requirementSpecification clause, installation route, and the person responsible for approvalKeep the record open until a compliance decision is reached

This table is Quad Bilişim’s original procurement record example; it is not a certificate or proof that a regulatory check is complete. If the quoted product code differs from the code on the delivered box, matching cable colors are not enough to close the record. Keep the change justification, equivalence documentation and authorized approval together.

What does this check not replace?

This guide does not prescribe one mandatory fire classification for every office in Türkiye. Qualified project professionals must assess the building use, route, project conditions and applicable requirements. A reaction-to-fire classification is not a guarantee of how long a circuit continues operating during a fire or of the safety of an entire building.

Document verification is not a substitute for data transmission testing of the installed cabling. In addition to procurement and delivery records, data cabling test report and Cat6/Cat6A selection criteria examine these separately. For an office renovation project in Istanbul, including this list in the project scope/survey file makes it easier to track material selection alongside the scope of implementation.

What does NPD mean in a DoP?

NPD (No Performance Determined) in a declaration of performance means that no performance is declared for the characteristic concerned. Do not read it as a failed test for the entire cable or a numerical value of zero; check which row it belongs to.

A document may declare a reaction-to-fire class in one row and show NPD for another characteristic. Do not apply NPD to other rows; a declared class does not mean that the characteristic marked NPD has been measured.

Document entryHow to record itWhat not to conclude
NPDRecord the characteristic, the exact declaration and the document version together.NPD is not a zero value or a failed test result.
Reaction-to-fire classKeep the full class with the DoP reference for the same product code.It does not demonstrate a passed Cat6/Cat6A transmission test.
Blank or illegible fieldAsk the manufacturer for a legible document covering the product.Do not fill a blank field with NPD or a pass on your own.

LSZH and CPR: Example record for a document clarification

DoP reference: [ ] · Version / date: [ ] · Characteristic: [ ] · Declared value: [ ] · Evidence required by the project: [ ] · Clarification request / owner: [ ]

This is an original document-review example from Quad Bilişim; do not alter the manufacturer’s declaration of performance. If the evidence required by the project is missing, keep the issue open for a qualified project lead. This section explains document reading; it does not prescribe one class for every building in Türkiye or establish legal compliance.

Additional primary sources on NPD

Evaluate the office cabling scope through its documentation

Structured cabling service You may share your current plan, cable references, and delivery expectations for this purpose. Contact Quad Bilişim.

Technical resources

Source verification: November 2, 2026. The evaluation table, procedural steps, and hypothetical examples are original recommendations by Quad Bilişim; they do not constitute a guarantee of price or outcome.

Quad Bilişim

Since 2012, we have aligned businesses’ technology needs with their workflows.

GET IN TOUCH

+90 850 474 33 34 info@quadbilisim.com

Meşrutiyet Mah. Seyrantepe Cad.
No:10 /J, Şile / İstanbul

© 2026 Quad Bilişim